Nic | GTS-21 | Epi | |||||||
---|---|---|---|---|---|---|---|---|---|
Parameter | Fast | Int | Slow | Fast | Int | Slow | Fast | Int | Slow |
A/C m (-pA/pF) | 213 ± 12 | 91 ± 7 | 65 ± 3 | 162 ± 23 | 70 ± 71-150 | 13 ± 21-150 | 161 ± 40 | 295 ± 371-150 | 112 ± 81-150 |
τ (ms) | 16 ± 1 | 174 ± 16 | 3360 ± 250 | 19 ± 3 | 84 ± 81-150 | 690 ± 1001-150 | 28 ± 61-150 | 170 ± 28 | 1880 ± 2001-150 |
All values are presented as mean ± S.E.M., and were derived from whole-cell current responses to 20 μM Nic (n = 91), 30 μM GTS-21 (n = 19) or 30 μM Epi (n = 20), all applied for 2.5 s at −70 mV. In each case, specific peak currents (in pA/pF) and time constants (τ) are tabulated for the fast, intermediate, and slow kinetic components, determined as described under Materials and Methods and in Fig. 1.
Int, intermediate.
↵1-150 Significant difference (p < 0.05) compared with those obtained with Nic.