TABLE 2

Curve-fit values for wild-type and T6′F mutant α7 responses to ACh

Data represent curve values generated by the Hill equation (see Materials and Methods) for macroscopic responses from oocytes expressing either indicated receptor.

Normalized Imax Hill Coefficient EC50
Rat α7 wild-type
ACh peaka
ACh net charge 1.05 ± 0.02 1.5 ± 0.1 16.5 ± 1.0 μM
Rat α7 T6′F mutant
ACh peak 0.89 ± 0.04 1.5 ± 0.4 1.7 ± 0.4 μM
ACh net charge 0.96 ± 0.04 2.4 ± 1.1 1.1 ± 0.2 μM
  • a The use of peak responses has been shown to provide inaccurate estimates of these parameters (Papke and Papke, 2002) and curve-fitting was thus restricted to net charge analysis for wild-type α7.