TABLE 2

Hidden Markov maximum interval likelihood fitting of the steady-state currents

Idealized current records were fitted to the gating scheme as described in Fig. 7. All rates have units of s−1. Data are mean ± S.E.M. from patches containing one active channel fitted individually. The rates were compared by unpaired t test.

Rates0 Calcium0.5 Calcium
Control (n = 9)PS (n = 5)Control (n = 5)PS (n = 6)
s−1
C1→C295 ± 5160 ± 20**115 ± 3085 ± 15
C2→C145 ± 5140 ± 40**50 ± 1535 ± 5
C2→C3260 ± 10485 ± 120*230 ± 35180 ± 15
C3→C2865 ± 90825 ± 190830 ± 220410 ± 40
C3→O1735 ± 60860 ± 140825 ± 115640 ± 75
O1→C31665 ± 150630 ± 80***1280 ± 1352130 ± 220**
O1→O21230 ± 340825 ± 515920 ± 23070 ± 30**
O2→O11655 ± 280885 ± 2301745 ± 480815 ± 290
C1→D12.1 ± 0.41.4 ± 0.33.0 ± 1.41.7 ± 0.5
D1→C11.3 ± 0.30.4 ± 0.10.8 ± 0.20.7 ± 0.2
C2→D24.6 ± 1.211.3 ± 4.48.4 ± 1.95.5 ± 2.0
D2→C215.8 ± 1.525.7 ± 6.318.0 ± 4.215.6 ± 4.0
  • * P < 0.05; **P < 0.01; *** P < 0.001.